首页 > 技术文章 > UPF

littleMa 2019-06-24 22:59 原文

1、UPF in SOC:

 

1、设定实施约束的层次

set_design_top SoC/Video_SB   #指定design_top为Video_SB

set_scope .             #指定命令作用的范围为当前层次即Video_SB

set_scope V1/LV1        #指定命令作用的范围为V1/LV1

 

2、设定设定power_domain

Video_SB top层次下存在下面5个domain和sub_domain

Video_SB/Video_PD、Video_SB/V1_PD、Video_SB/V2_PD、Video_SB/LV12_PD、Video_SB/LV34_PD

设定power_domain的步骤如下:

1. set_scope  Video_SB                #set the scope to Video_SB 

2. create_power_domain Video_PD -include_scope       #create Video_PD power domain in current scope.

3. create_power_domain V1_PD -elements {V1}       #creates V1‘s domain,its own power domain called V1_PD

4. create_power_domain LV12_PD -elements {V1/LV1 V1/LV2}

5. create_power_domain V2_PD -elements {V2}

6. create_power_domain LV34_PD -elements {V2/LV3 V2/LV4}

 

3、描述power_domain的电源网络: Supply Network 

power domain中电源网络的定义如下图:

主要是通过下面四个进行电源网络的连接。

create_supply_port   VDD   -direction in
create_supply_port   VSS   -direction in

create_supply_net    Pwr     -domain Video_PD
create_supply_net    Gnd    -domain Video_PD

connect_supply_net   Pwr   -ports (VDD)
connect_supply_net   Gnd   -ports (VSS)

set_domain_supply_net   Video_PD \
-primary_power_net   Pwr \
-primary_ground_net   Gnd

下图中,V_PD domain 中的supply_net复用Video_PD domain中的supply_net。需要-reuse进行描述

create_supply_net   Pwr    -reuse   -domain V_PD
create_supply_net   Gnd   -reuse   -domain V_PD 

同时,必须显示的申明net所属的power_domain

set_domain_supply_net V_PD \
-primary_power_net Pwr \
-primary_ground_net Gnd

 

4、创建power_switch

 

create_supply_net  VDDsw -domain V_PD   #定义switch产生的supply_net。

create_power_switch SW -domain V_PD \
-input_supply_port {pwin Pwr} \
-output_supply_prt {pwout VDDsw } \
-control_port {swctrl sw_ctrl} \
-on_state {Pwon swctrl} \
-off_state {Pwoff !swctrl}

set_domain_supply_net V_PD \     #V_PD的primary_power_net为switch产生的net
-primary_power_net VDDsw \
-primary_ground_net Gnd

5、设定Supply Port的值

add_port_state    VDD              -state   {ON_10  1.0}    #VDD只有一种常开的状态,其电压值为1.0v

add_port_state    VSS               -state  {ON_00  0.0}

 add_port_state   SW/VDDsw   -state   {ON_10  1.0}   -state   {OFF  off}    #switch开关电压VDDsw,存在ON和OFF两种状态。

 

6、Power State Table的描述

create_pst   PST1   -supplies   {VDD, VDDsw, VDD2, VSS}

add_pst_state   Normal   -pst PST1 -state {ON_10, ON_10, ON_08, ON_00}
add_pst_state   Sleep     -pst PST1 -state {ON_10, OFF, ON_08, ON_00}
add_pst_state   Normal   -pst PST1 -state {ON_10, OFF, OFF, ON_00}

 

7、set retention快速回复被关断domain的状态

其中retention cell的电源和地为红色VDD和VSS

set_retention V_PD_retention \     #所以V_PD domain的状态都要能被恢复
-domain V_PD \
-retention_power_net Pwr \
-retention_ground_net Gnd

 set_retention_control V_PD_retention \
-domain V_PD \
-save_signal {SRctrl posedge} \
-restore_signal {SRctrl negedge}

 

8、用isolation cell 隔离ON domain和OFF domain

OFF domain 其输出连接至ON domain,所以其输出需要处理。

 

set_isolation V_PD_isolation \
-domain V_PD \
-applies_to outputs \
-clamp_value 0 \
-isolation_power_net Pwr \
Isolation_ground_net Gnd 

set_isolation_control V_PD_isolation \
-domain V_PD \
-isolation_signal vISO \
-isolation_sense high \
-location parent

 

9、level shift cell 处理不同电压域之间信号的传递。

set_level_shifter LV_PD_LS
-domain LV_PD \
-threshold 0.1 \
-applies_to both \
-rule both \
-location self




  

 

推荐阅读